fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/2017-final-report-international-class.pdf
hydro power; 69 𝑃 = 𝜂𝜌𝑔𝑄𝐻 1000 Where: P is Power output in kW H is the net head in meters η is the overall efficiency of power plant ρ is the density of water [1000 kg/m³] g is the acceleration due [...] [BM3] 1,000 £ NPV vs. Investment costs Investment -20% Investment +20% 534 542 537 -319 -324 -326 -400 -200 - 200 400 600 Export to the grid [BM1] VPW with SSE [BM2] VPW with local sales [BM3] 1,000 £ NPV [...] hourly profile, the demand will be higher since water heating is still required. - 200 400 600 800 1.000 1.200 0 0 h 3 0 0 1 h 3 0 0 2 h 3 0 0 3 h 3 0 0 4 h 3 0 0 5 h 3 0 0 6 h 3 0 0 7 h 3 0 0 8 h 3 0 0
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/ic-2016-the-assessment-of-renewable-energy-projects-for-community-benefit-in-west-harris.pdf
-300 -200 -100 0 100 200 300 200 300 400 500 600 N P V ( x 1 0 0 0 P o u n d s) Investment costs (x 1000 Pounds) Luskentyre 94m head, 60 kW capacity: Investment costs and resultant NPV 5.92 p/kWh 10 p/kWh [...] -200 -100 0 100 200 150 200 250 300 350 400 450 N P V ( x 1 0 0 0 P o u n d s) Investment costs (x 1000 Pounds) Luskentyre 54m head, 35 kW capacity: Investment costs and resultant NPV 5.92 p/kWh 10 p/kWh [...] -400 -300 -200 -100 0 100 200 200 300 400 500 600 N P V ( x 1 0 0 0 P o u n d s) Investment costs (x 1000 Pounds) Luskentyre 72m head, 50 kW capacity: Investment costs and resultant NPV 5.92 p/kWh 10 p/kWh
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/potential-of-renewable-energy-in-the-north-harris-trust-area-2005-.pdf
459 £73 2.4% Spare parts % 0.50% £45,565 £228 7.6% O&M labour p-yr 1 £1,000 £1,000 33.3% Travel and accommodation p-trip 1 £1,000 £1,000 33.3% General and administrative % 10% £2,483 £248 8.3% Contingencies [...] 459 £73 2.4% Spare parts % 0.50% £45,565 £228 7.6% O&M labour p-yr 1 £1,000 £1,000 33.3% Travel and accommodation p-trip 1 £1,000 £1,000 33.3% General and administrative % 10% £2,483 £248 8.3% Contingencies [...] 4175 Pyrtec 500 380 - 530 2200 2539 1210 5590 Pyrtec 650 480 - 680 2398 2789 1210 6680 Pyrtec 1000 720 - 1000 2760 3406 1610 10695 1 http://www.3genergi.co.uk/Kob%20Pyrtec.html date 7.09.05 Potential of
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/the-ecological-footprint-of-the-sleat-peninsula-2008-.pdf
Table 5.6 Transport Footprint by Sector Water Demand Residential Commercial Public -Passenger km (1000 km) 13,088.92 306.22 1,395 % of transport mode- km 88.50 2.07 9 Total CO2 Emissions in tonnes 3,456
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/towards-sustainable-energy-a-roadmap-for-residential-buildings-at-loop-head-ic-2022.pdf
for the economic calculation throughout the study. Investment and O&M Cost -3.000% -2.000% -1.000% 0.000% 1.000% 2.000% 3.000% 4.000% 5.000% 6.000% 19 8 6 19 8 8 19 9 0 19 9 2 19 9 4 19 9 6 19 9 8 20 0 0 [...] 23.00 23.00 Mounting system – ground mount Set. 1 223.00 223.00 System labeling sticker Nos. 1 10.00 10.00 The total cost of Material (Including 23% VAT) 3054 Cost of installation (Labour & transport) Work [...] 23.00 23.00 Mounting system – ground mount Set. 1 412.00 412.00 System labeling sticker Nos. 1 10.00 10.00 The total cost of Material (Including 23% VAT) 2907.00 Cost of installation (Labour & transport)
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/the-transport-sector-in-rousay-and-eday-energy-cost-and-emissions-compared-to-kirkwall-2010-.pdf
following chapters. Basic assumptions for the calculation are as follows: Diesel Petrol Unit LHV14 10.00 8.80 kWh/Liter CO2 emission factor15 2.63 2.30 kg CO2/Liter 13 Interviews with Eday and Rousay fuel [...] the people of Rousay and Eday spend between 0 and 2000 £/year and in Kirkwall between 0 - 29 - and 1000 £/year on transport. Moreover the histograms show us that the majority of the people of the sample [...] Rousay Eday House material transport cost from Kirkwall £0 £2,400 £2,513 Borehole construction £0 £1,000 £0 Borehole pump cost £0 £772 £0 Water connection to the local grid £0 £0 £700 Electricity connection
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/options-for-development-of-community-wind-energy-projects-in-the-north-isles-of-shetland-2007-.pdf
of the proposed system Configurations Units Battery 1 2 3 4 Max power fed into the grid 1,000 600 1,000 1,000 kW Battery Power 800 600 600 800 kW Storage capacity 2,000 900 1,500 2,000 kWh Storage Duration [...] –The maximum capacity to be fed into the grid is 1000 KW. The flow battery has a discharge capacity of 600 KW and a storage capacity of 1500 KWh 0 500 1000 1500 2000 2500 0 1 2 3 4 5 6 7 8 9 10 11 12 13 [...] .......................55 Figure 5.3. Scenario 2 –The maximum capacity to be fed into the grid is 1000 KW. The flow battery has a discharge capacity of 600 KW and a storage capacity of 1500 KWh ......
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/exploring-sustainable-energy-options-for-loop-head-ic-2021.pdf
depicted Figure 4-4, assuming that fuel technology are the same across all districts. 0 200 400 600 800 1000 1200 1400 M W h Districts Total heat demand in cold and hot season in Loop Head Total heating demand [...] PV System Investment cost [€/kW] O & M Cost [€/kW/a] Lifetime [Year] Discount Rate (%) PV Community 1000 10 20 3.5 % PV Farm 1200 5 20 3.5 % Rooftop PV in Residential household 1200 5 20 3.5 % Rooftop PV
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/assessment-of-renewable-energy-technologies-for-the-sustainable-development-of-the-isle-of-jura-2012-.pdf
182 0.132 0.094 0.063 0.048 0.037 0.032 0.000 0.100 0.200 0.300 0.400 0.500 0.600 0.700 0.800 0.900 1.000 1.100 1.200 1.300 1.400 1.500 Fl o w ( m 3 / s) Percentile Flow Duration Curve of Corran River FDC
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/sesam-african-workshop-2008-final.pdf
expert Ethiopian Science and Technology Agency Ethiopian Cleaner Production Centre P. O. Box 21931code 1000 Addis Ababa Ethiopia Tel: +251 911 626207 (Mobile) alemayehuz2001@yahoo.com Abstract: Modern sources [...] commercialization, financing and extension. As a result, the pilot would establish between 500 and 1000 domestic biogas cores. The pilot shall provide detailed information and justification for the potential [...] Services (AES) SONEL is the main provider of electricity in Cameroon. It has to produce a maximum of 1000 MW which is currently its installed capacity. Over 80 percent of its production is generated from