fileadmin/content/zentren/ices/bilder/veranstaltungen/lesekreis/pistor-2019-code-of-capital.pdf
org /media /ac6b533f -3 /5a7c32f8 -pdf/. 55. For details see the US Federal Reserves, 12 CFR Parts 217, 249, and 252 available online at https:// www .gpo .gov /fdsys /pkg /FR -2017 -09 -12 /pdf /2017–19053 [...] http:// www .gao .gov /new .items /d09161 .pdf. 33. Lehman’s stock chart for the last 12 months of its existence is available online at http:// www .ino .com /blog /2008 /09 /looking -back -3 -key -signs [...] ” New York Times, May 21, 2016, available online at https:// www .nytimes .com /2016 /05 /22 /business /dealbook /crypto -ether http://fcic-static.law.stanford.edu/cdn_media/fcic-docs/2007-07-27_Goldm
fileadmin/content/seminare/soziologie/dokumente/culture-practice-and-europeanization/cpe-vol.5-no.1-2020/cpe-5-1-pp16-33-fage-butler-gorbahn-2020.pdf
(80), European (91), European Capital of Culture (61), Europeans (3), EU (7), continent / continents (5), euro / euros (2), eutopia (8), euroin- vasion (4) Regional dimension (Total number: 175) Jutland* [...] discourse is reflected in words such as “new”, “future”, “create”, “change”, “innovate”, “transform / transformation”, “vi- sion”, “flux” and by a focus on young people. The discourse of transformation
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/association-of-indonesian-alumni-of-university-of-flensburg-proceeding-v2-20161030.pdf
63 BOE / capita (0.64 TOE/capita) with the electricity consumption is only 764 kWh / capita. As a comparison, Malaysia and Singapore have already reached about 2,674 kWh / capita and 7.403 kWh / capita [...] and was approved by the Decree of the Minister of Energy and Mineral Resources (ESDM) No. 0074K / 21 / MEM / 2015 The total installed power generation capacity in Indonesia by the end of 2014 reached 53 [...] with log C while Langmuir describes the curve 1 / q with 1 / C. Value of q is the ratio of the mass of absorbed water to mass nanozeolite 3Å (g water / g nanozeolite 3Å). Value of q is obtained from mass
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/integrating-renewable-energy-technology-for-heat-demand-and-a-hydrogen-economy-for-unst-ic-2019.pdf
1-5 MW (£ / kW) 130.5 (Danish Energy Agency, 2018a, p. 227, Technology Data for Energy Plants for Electricity and District Heating Generation.) Fixed O&M (£ / kW / a) 930.9 Variable O&M (£ / kWh output) [...] for thermal storage Indicator Value Source Capex (£ / kWh) 3 (Danish Energy Agency, 2018b, p. 59, Technology Data for Energy Storage) Fixed O&M (£ / kWh / a) 1 Round Trip Efficiency (%) 98 Technical Life [...] production) through workshops, newspaper articles or the media. • Job creation by utilizing local skills / expertise, initiating apprenticeship programs, and highlighting any other value addition to the community
fileadmin/content/abteilungen/industrial/dokumente/downloads/veroeffentlichungen/diskussionsbeitraege/znes-discussionpapers-008-100ee-mahe.pdf
airport and internationally available solar data (NASA 2016) used for a coordinate close to Mahé (4.5°S / 55.625°E). As the subject is of great interest to key players from the civil society and from government [...] Comparisons with the wind speed data from the global (NASA 2016) 2 data set for the coordinate 4.5°S / 55.625°E and measurement data from eight existing wind turbines at the inner harbour of Mahé and data [...] Mahé internationally available MERRA 2 solar radiation data was used, which are available for 4.5°S / 55.625°E (NASA 2016). An annual total useful irradiation of 2,071 kWh/m2 is reported for this coordinate
fileadmin/content/abteilungen/industrial/dokumente/downloads/veroeffentlichungen/diskussionsbeitraege/znes-discussionpapers-009-100ee-praslin-ladigue.pdf
available wind and solar data (NASA 2016) reported for a coordinate close to Praslin and La Digue (4.5°S / 55.625°E). As the subject is of great interest to key players from the civil society and from government [...] performed hourly wind speed data from the global MERRA 2 data set (NASA 2016) for the coordinate 4.5°S / 55.625°E have been used. As these NASA data sets calculated from satellite data have proven to overestimate [...] Digue internationally available MERRA 2 solar radiation data were used, which are available for 4.5°S / 55.625°E (NASA 2016). An annual total useful irradiation of 2,071 kWh/m2 is reported for this coordinate
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/assessment-of-renewable-energy-technologies-for-the-sustainable-development-of-the-isle-of-jura-2012-.pdf
operate a 50 kW CHP unit is 190,368 m 3 / year and the biggest biogas generation potential that can be generated from the Jura Distillery is about 613,000 m 3 / year. Nevertheless, to get the biggest [...] Jura community and highlights possible environmental impact assessment requirements as well as legal / authorization aspects. 4.3 Methodologies The study was performed in the order shown in Figure 4-1. Figure [...] 100 0.200 0.300 0.400 0.500 0.600 0.700 0.800 0.900 1.000 1.100 1.200 1.300 1.400 1.500 Fl o w ( m 3 / s) Percentile Flow Duration Curve of Corran River FDC Intake 1 FDC Intake 2 FDC Intake 3 ASSESSMENT
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/1.-eem-international-class-2015-achiltibuie-final.pdf
Community Hall - - 1 (peak demand 80kW) £9,850 - £2.5 / kW Achiltibuie Primary School - - 1 (peak demand 49 kW) £4,280 £9,000 (Assumed: 2 Semi-Detached) £2.5 / kW Total DHN Investment £253,372 Operation Pumping [...] Connection .......................................................... 81 Figure 12-2: Income Degression / FIT Periods (33 kV) .......................................................... 82 Figure 12-3: 33 kV [...] 11KV grid under different feed-in constraints .............. 89 Table 14-3: Gains and Losses – CCDC / CWP – Private Wire (11 kV) .................................. 91 Table 14-4: District Heating Financial
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/alumni/the-assessment-of-renewable-energy-projects-for-community-benefit-in-west-harris.pdf
140 160 180 0 0,1 0,2 0,3 0,4 0,5 P o w e r kW / E n e rg y M W h Design flow (m³/s) Power Energy 0 50 100 150 200 250 0 0,1 0,2 0,3 0,4 0,5 P o w e r kW / E n e rg y M W h Design flow (m³/s) Power Energy [...] suggested by the respondents: Daily Midday / Daily Every 2 hours From 9am onwards, every 3-4 hours Time suggestion: 10am,2pm,6pm 3 times daily at 10am, 2pm. 4pm / 2 times daily at 10am, 4pm 2 times daily [...] Tailleir River to maximize on the 200 kW grid access that has been granted; b) small -hydro plant or / and wind turbines close to the townships of Luskentyre and Seilebost; c) a 1MW wind project in the Laxdale
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/ic-2016-the-assessment-of-renewable-energy-projects-for-community-benefit-in-west-harris.pdf