Search narrowed by:
Remove all filters
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/assessment-and-future-scenarios-of-knoydarts-electricity-system-2013-.pdf
2013. 2 EXECUTIVE SUMMARY This report has been prepared for the Knoydart Foundation to provide a basis for making decisions on the development of community-owned energy projects on the Peninsula of Knoydart [...] but unexpected shutdowns occur at 180 kW. The energy output is stored in the monitoring system on a basis of average half hourly. These values do not give the maximum power that the hydropower plant can generate [...] relationship between periodical rainfall and spillway flow. It is possible to do this on a seasonal basis for different periods to account for different meteorological conditions. However, since the spillway
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/2017-final-report-international-class.pdf
Firstly, the heat energy cost (see Table 8) for different heating fuels used has been deduced on the basis of several factors such as standard rates of fuels in Durness (information collected while interviewing) [...] (Scottish heat map) Encompassing the above-mentioned criteria, the team decided to build the study on the basis of heating demand (3.34 GWh) estimated from Heat Demand Profile Estimator. 4.3 Energy Demand Estimation [...] annual energy consumption of the microbrewery premises reaches 175 MWh, however it is computed on the basis of preliminary data and will certainly change as the design matures. Area/Process in Microbrewery
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/potential-of-renewable-energy-in-the-north-harris-trust-area-2005-.pdf
the special protection area (SPA) of the Scottish Natural Heritage The study was carried out on the basis of the following assumptions: 1. The flow of the river has been analyzed based on the rainfall data [...] Total Timber Harvest Total Brash Harvest Total Thinning Harvest Source: Author’s calculation On the basis of the calculated average Volume/Weight Ratio 1.065m3 /tonne (Appendix 4.4.1), the harvest quantity [...] Wood 4364 m 3 /1.065m 3 /tonne = 4097 tons The calorific value of wood fuel can be determined on the basis of the moisture content of the wood shown in Appendix 4.4.2 (Reforesting Scotland, Highland Birchwoods
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/options-for-development-of-community-wind-energy-projects-in-the-north-isles-of-shetland-2007-.pdf
producing hydrogen/electricity from wind as a fuel for vehicle. The findings of the survey were the basis for developing ideas for possible concepts how to reduce the intermittence of electricity production [...] SHEPDL and the University of Strathclyde up to 21 MW could be accommodated in the grid on a non-firm basis. However this is only possible if the Sullom Voe power station is connected to the grid and balances [...] MWh which constitutes 14% and 86% respectively of the annual commercial heat demand. Yell On the basis of the SESAM survey, the total heat demand in Yell is estimated at 12,560 MWh/year. Out of the total
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/the-ecological-footprint-of-the-sleat-peninsula-2008-.pdf
Hence by converting both cropland and pasture into global hectares, they can be compared on an equal basis. Yield factor: This is the ratio between productivity of a given land type to the global world average [...] the impacts of the activities of the community of Sleat on the environment and also provides the basis for suggestions on how the community can minimize such impacts through use of renewable energy. Therefore
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/the-transport-sector-in-rousay-and-eday-energy-cost-and-emissions-compared-to-kirkwall-2010-.pdf
to go to the mainland. The transport energy demand and the emissions were calculated on the same basis. In Rousay the CO2 emissions related to transport on the island and between the island and Kirkwall [...] like to encourage the local organisations and communities to use the results of this report as a basis for further research to achieve suitable transport systems for the islands. xii Bibliography Printed
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/community-development-projects-for-the-supply-of-heat-and-electricity-from-renewables-in-the-isles-of-barra-and-vatersay-2009-.pdf
biogas content, and Community Energy Scotland for waste amounts 25 This percent was arrived at on the basis of the other figures provided for organic waste and residue waste which were desegregated by region
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/ic-2014-applecross-report.pdf
average flow data as well as monthly power production from the pre- feasibility studies provided the basis for the selection of sites for further assessment. Depending on the potential and the residential [...] Lochcarron garage provides services twice a week on Wednesday and Saturday. The bus operates on a demand basis. Commuters would have to book in advance. The journey commences at 07:45 at Toscaig and returns to
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/towards-sustainable-energy-a-roadmap-for-residential-buildings-at-loop-head-ic-2022.pdf
100 % and even more of total generation if the total demand experiences an increase on an annual basis. Seeing the outcome from the synergy with the engagement of the community, the IC2021 sustained the [...] the team arrived in Loop Head. However, for precaution, the team was tested for COVID on a weekly basis. 3. Case study approach to energy efficiency and technologies 3.1. Common definitions used throughout [...] different heat pumps in the European heat pumps market, 40,358 European workers are employed on full-time basis, which in return foster employment in the European Union(European Heat Pump Association, 2021). Heat
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/exploring-sustainable-energy-options-for-loop-head-ic-2021.pdf
energy system, an excel energy modelling tool was developed for Loop Head. This tool will provide the basis for investment decisions, support operational decisions, and perform scenario analysis. It is designed [...] Model 2021, was developed in Microsoft Excel. The tool was developed with an objective to provide the basis for investment decisions, support operational decisions, and serve as a platform for different st [...] Demand The Loop Head’s farming sector consumes, approximately 2,770 MWh of electricity on annual basis. For calculating the Farming Sector’s electricity demand, the farming sector was divided into three