Search narrowed by:
Remove all filters
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/assessment-of-renewable-energy-technologies-for-the-sustainable-development-of-the-isle-of-jura-2012-.pdf
182 0.132 0.094 0.063 0.048 0.037 0.032 0.000 0.100 0.200 0.300 0.400 0.500 0.600 0.700 0.800 0.900 1.000 1.100 1.200 1.300 1.400 1.500 Fl o w ( m 3 / s) Percentile Flow Duration Curve of Corran River FDC
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/ic-2014-applecross-report.pdf
COMBINATION SOURCE: AUTHORS 0.00 5.00 10.00 15.00 20.00 25.00 Jan Feb Mar Apr May Jun July Aug Sep Oct Nov Dec En er gy (M W h) Hydropower Main Grid 0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 Jan Feb [...] the demand, extra electricity will be needed from the main grid. If additional electricity is 0.00 10.00 20.00 30.00 40.00 50.00 Jan Feb Mar Apr May Jun July Aug Sep Oct Nov Dec En er gy (M W h) Combined [...] the households considered in Burnside will be met by the micro-hydropower scheme only. 0.00 5.00 10.00 15.00 20.00 25.00 30.00 Jan Feb Mar Apr May Jun July Aug Sep Oct Nov Dec En er gy (M W h) Hydropower
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/towards-sustainable-energy-a-roadmap-for-residential-buildings-at-loop-head-ic-2022.pdf
for the economic calculation throughout the study. Investment and O&M Cost -3.000% -2.000% -1.000% 0.000% 1.000% 2.000% 3.000% 4.000% 5.000% 6.000% 19 8 6 19 8 8 19 9 0 19 9 2 19 9 4 19 9 6 19 9 8 20 0 0 [...] 23.00 23.00 Mounting system – ground mount Set. 1 223.00 223.00 System labeling sticker Nos. 1 10.00 10.00 The total cost of Material (Including 23% VAT) 3054 Cost of installation (Labour & transport) Work [...] 23.00 23.00 Mounting system – ground mount Set. 1 412.00 412.00 System labeling sticker Nos. 1 10.00 10.00 The total cost of Material (Including 23% VAT) 2907.00 Cost of installation (Labour & transport)
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/exploring-sustainable-energy-options-for-loop-head-ic-2021.pdf
depicted Figure 4-4, assuming that fuel technology are the same across all districts. 0 200 400 600 800 1000 1200 1400 M W h Districts Total heat demand in cold and hot season in Loop Head Total heating demand [...] PV System Investment cost [€/kW] O & M Cost [€/kW/a] Lifetime [Year] Discount Rate (%) PV Community 1000 10 20 3.5 % PV Farm 1200 5 20 3.5 % Rooftop PV in Residential household 1200 5 20 3.5 % Rooftop PV
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/potential-of-renewable-energy-in-the-north-harris-trust-area-2005-.pdf
459 £73 2.4% Spare parts % 0.50% £45,565 £228 7.6% O&M labour p-yr 1 £1,000 £1,000 33.3% Travel and accommodation p-trip 1 £1,000 £1,000 33.3% General and administrative % 10% £2,483 £248 8.3% Contingencies [...] 459 £73 2.4% Spare parts % 0.50% £45,565 £228 7.6% O&M labour p-yr 1 £1,000 £1,000 33.3% Travel and accommodation p-trip 1 £1,000 £1,000 33.3% General and administrative % 10% £2,483 £248 8.3% Contingencies [...] 4175 Pyrtec 500 380 - 530 2200 2539 1210 5590 Pyrtec 650 480 - 680 2398 2789 1210 6680 Pyrtec 1000 720 - 1000 2760 3406 1610 10695 1 http://www.3genergi.co.uk/Kob%20Pyrtec.html date 7.09.05 Potential of
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/present-situation-sustainable-energy-scenario-of-lochboisdale-up-to-2014-2009-.pdf
£ - UK Pound Conversions 1 inch - 2.54 Centi Meter 1 kWh - Kilo-Watt Hour 1 Ton - 1000 kg 1 MW - 1000 kW 1 MWh - 1000 kWh xi Executive Summary In February 2009, the Storas Uibhist has hosted a study visit
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/sesam-african-workshop-2008-final.pdf
expert Ethiopian Science and Technology Agency Ethiopian Cleaner Production Centre P. O. Box 21931code 1000 Addis Ababa Ethiopia Tel: +251 911 626207 (Mobile) alemayehuz2001@yahoo.com Abstract: Modern sources [...] commercialization, financing and extension. As a result, the pilot would establish between 500 and 1000 domestic biogas cores. The pilot shall provide detailed information and justification for the potential [...] Services (AES) SONEL is the main provider of electricity in Cameroon. It has to produce a maximum of 1000 MW which is currently its installed capacity. Over 80 percent of its production is generated from
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/alumni-workshop-report-part1.pdf
Hong Ky, Worldbank, Vietnam 09:30 - 10:00 Challenge to Implementation: Waste Energy from Palm Oil in Indonesia Prof. Dr. Ir. H. Didik Notosudjono Msc, Indonesia 10:00 - 10:30 Solar Thermal Energy Application [...] Institute of Meteorology and Hydrology Ministry of Natural Resources and Environment, Vietnam. 9:30 - 10:00 Preliminary Lessons for Vietnam from the World Bank's ongoing Economics of Adaptation to Climate Change [...] Change Study: global track and Vietnam country case study. Dr. Douglas J. Graham, World Bank, Vietnam. 10:00 - 10:30 Tea/Coffee Break 10:30 - 11:00 Renewable energy development in Vietnam - Current situation
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/alumni-workshop-report-part2-1.pdf
The simplified formula is BG = VS /1000 * n * 365 * Bo * MCF * WCH4 * DCH4 *GWP Where VS = volatile solid excreted by animal (kg/head/d) n = number of animal (head) 1000 = conversion (kg/t) 365 = days that [...] (The Jakarta post, 2007). The risk of sea level rise to Indonesia, areas with density of more than 1000 people/sq km are 115 areas which will get hit the most by level rise. In total of 41.6 million people [...] Risk of climate change Background of BangladeshBackground of Bangladesh Population 153 million (about 1000 per sq km) Two basic resources natural gas and coal Gas Reserves 14.4 tcf. Estimated to last until
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/options-for-development-of-community-wind-energy-projects-in-the-north-isles-of-shetland-2007-.pdf
of the proposed system Configurations Units Battery 1 2 3 4 Max power fed into the grid 1,000 600 1,000 1,000 kW Battery Power 800 600 600 800 kW Storage capacity 2,000 900 1,500 2,000 kWh Storage Duration [...] –The maximum capacity to be fed into the grid is 1000 KW. The flow battery has a discharge capacity of 600 KW and a storage capacity of 1500 KWh 0 500 1000 1500 2000 2500 0 1 2 3 4 5 6 7 8 9 10 11 12 13 [...] .......................55 Figure 5.3. Scenario 2 –The maximum capacity to be fed into the grid is 1000 KW. The flow battery has a discharge capacity of 600 KW and a storage capacity of 1500 KWh ......