Search narrowed by:
Remove all filters
fileadmin/content/portal/studium-und-lehre/dokumente/formulare-und-bescheinigungen/bescheinigung-pruefungsunfaehigkeit-aerztliches-attest.pdf
S 75/16; BayVGH - Beschluss vom 13.09.2017 - 7 ZB 17.633; VG Würzburg – Beschluss vom 24.01.2018 – W 2 E 17.1376). Zur Beurteilung dieser Rechtsfrage und zum Nachweis einer die Prüfungsunfähigkeit begründenden
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/a-sustainable-energy-model-for-a-circular-economy-a-case-study-of-creed-integrated-waste-management-facility-stornoway-western-isles.pdf
Output of Wind Turbine 300 kW Max Export to Grid Set by DNO 225 kW Max Export Limit Set by IWMF (to ensure limit is not exceeded and more electricity can be used within IWMF) 200 kW Min and Max Output Limit [...] reaction formula Auxiliaries 4 kW (Browne, 2016) Table 38: 30 kW Electrolyser parameters for model 72 Figure 5-1: Impact of hydrogen production on the efficiency of a 30kW electrolyser 5.2 Algorithm Development [...] approximately 60 kW and the characteristics of the same are shown in Table 41. Electrolyser 2 Quantity Unit Source Maximum operative power 58 kW (Pure Energy Centre) Minimum operative power 12 kW (Gazey, 2014)
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/alumni/the-assessment-of-renewable-energy-projects-for-community-benefit-in-west-harris.pdf
160 180 0 0,1 0,2 0,3 0,4 0,5 P o w e r kW / E n e rg y M W h Design flow (m³/s) Power Energy 0 50 100 150 200 250 0 0,1 0,2 0,3 0,4 0,5 P o w e r kW / E n e rg y M W h Design flow (m³/s) Power Energy [...] assessed in this site as follows: Scenario 1: 100kW hydro and 100kW wind turbine Scenario 2: 100kW hydro with storage and 100kW wind turbine Scenario 3: 100kW hydro with storage and a larger wind scheme to [...] Scenario III: 100 kW Hydro + 200 kW Wind (2 x 100 kW Xant M-21) 7.7.1 Energy Assessment Under the current FIT scheme the same electricity price is paid for projects between 100kW to 1500kW. A third scenario
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/assessment-and-future-scenarios-of-knoydarts-electricity-system-2013-.pdf
scenario with 180 kW hydro and 160 kW Diesel, medium demand scenario with 250 kW hydro and 160 kW Diesel, high demand scenario with 250 kW hydro, new hydro site 85 kW and Diesel 160 kW ................. [...] scenario with 180 kW hydro and 160 kW Diesel, medium demand scenario with 250 kW hydro and 160 kW Diesel, high demand scenario with 250 kW hydro, new hydro site 85 kW and Diesel 160 kW Source: Own calculations [...] Hydro 180 kW and Diesel (Status Quo) 340 874,660 1579,23 0,58 8,602 2 Hydro upgraded with 250kW, Mhuilinn 85kW and Diesel standby 495 874,460 1571,59 0,58 0,463 3 Hydro upgraded with 250kW, Scottas Burn
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/2017-final-report-international-class.pdf
Limit Fulfilled? (800kW) (900kW) A (500kW) 45.0 25.2 25.4 21 1,102 YES (800kW) (900kW) B (500kW) 45.0 25.2 27.7 23.9 798 YES (800kW) (900kW) C (500kW) 45.0 25.2 25.4 21.7 995 YES 60 kW Craft village turbine [...] - 60 kW with FiT 60 kW without FiT 100 kW with FiT 100 kW without FiT N P V ( 1 ,0 0 0 £ ) Craft village private wire scenario comparison 60 kW with FiT 60 kW without FiT 100 kW with FiT 100 kW without [...] to be 5 % of the annual profit (Vidal, 2012). 800 kW Enercon 900 kW Enercon 500 kW Vestas HARBON 60kW XANT 100kW Unit Capacity 800 900 500 60 100 kW Gross Specific Yield 4754 3858 3862 3691.2 4544.7 kWh/kWp
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/ic-2014-applecross-report.pdf
turbine in the range of 1.5 to 10kW can generate about 1,200 – 4,300 kWh per installed kW generator capacity per year, at specific investment costs of around 6,000 GBP/kW. Depending on the priority of the [...] a micro wind turbine with a generation capacity from 1.5kW to 15kW in the United Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 0 1 2 3 4 5 6 W in d S pe ed (m /s ) Wind Resource 22 Towards a Greener [...] obtain the power of the boiler: 1. 0.05 – 0.06 kW for older non-insulated houses; 2. 0.04 – 0.05 kW for older houses with some insulation; 3. 0.03 – 0.04 kW for well-insulated or new build properties. TABLE
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/towards-sustainable-energy-a-roadmap-for-residential-buildings-at-loop-head-ic-2022.pdf
0.27 W/m2 ∙K First floor Pitched roof: insulated on rafter 0.49d W/m2 ∙K Second floor Pitched roof: insulated on rafter 0.25d W/m2 ∙K Ground floor (solid) 0.34d W/m2 ∙K Second floor (solid) 0.37d W/m2 ∙K [...] 2.1d W/m2 ∙K Wall 2 (Concrete block, 320 mm insulated) 1.64d W/m2 ∙K Roof (No insulation) 2.3d W/m2 ∙K Ground floor (uninsulated, solid) 0.61d W/m2 ∙K Windows (Single glazed metal frame) 5.7d W/m2 ∙K [...] found that these are single string inverters with a capacity of 1kW to 3kW and dual string inverters with capacity ranging from 2.5kW to 6kW. Those modern inverters come with in-built charge controllers for
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/exploring-sustainable-energy-options-for-loop-head-ic-2021.pdf
hourly demand (kW) Autumn weekend hourly demand (kW) Winter weekday hourly demand (kW) Winter weekend hourly demand (kW) Spring weekday hourly demand (kW) Spring weekend hourly demand (kW) Summer weekday [...] weekday hourly demand (kW) Summer weekend hourly demand (kW) 0 0.385 0.435 0.460 0.522 0.404 0.438 0.379 0.416 1 0.280 0.329 0.329 0.385 0.292 0.345 0.273 0.317 2 0.242 0.267 0.280 0.311 0.255 0.283 0.242 0 [...] Financial Parameters for PV system Financial Parameters Type of PV System Investment cost [€/kW] O & M Cost [€/kW/a] Lifetime [Year] Discount Rate (%) PV Community 1000 10 20 3.5 % PV Farm 1200 5 20 3.5 %
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/alumni-workshop-report-part1.pdf
community groups involved in large scale renewable energy projects, most of them wind projects of 800kW to 1 MW. A major problem in Scotland, especially for community wind projects, is the long planning process
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/alumni-workshop-report-part2-1.pdf
maxm maxmload (W) **Hours/day maxm 80x1 10Ax1, ptl 100AH x1 375W 6 0.40 80 5 80x2 20Ax1, ptl 150AHx1 375W 6 0.80 160 5 80x3 30Ax1,ptl 200AHx1 375W 6 1.20 240 5 100x3 30Ax1,ptl 150AHx2 750W 6 1.50 300 5 100x4 [...] ptl 200AHx2 750W 6 2.00 400 5 130x4 40Ax1,ptl 150AHx3 750W 6 2.60 520 5 130x5 40Ax1,ptl 200AHx3 750W 6 3.25 650 5 130x6 60Ax1,xan 150AHx5 1250W 6 3.90 780 5 130x7 60Ax1,xan 200AHx4 1250W 6 4.55 910 5 130x8 [...] 200AHx5 1250W 6 5.20 1040 5 100x12 40Ax2,ptl 200AHx6 1250W 6 6.00 1200 5 130x10 40Ax2,ptl 200AHx7 2012W 6 6.50 1300 5 180x8 40Ax1,ptl 150AHx8 2424W 6 7.20 1440 5 130x12 40Ax2,ptl 150AHx10 2012W 6 7.80 1560